EN
logologo

facebook Ënneschtgaass

EN

Banner Chonghong Industries Ltd.

Power Armored Kabel Spec. fir Ultraschall Ueleg Well

Power Armored Kabel Spec. fir Ultraschall Ueleg Well

1. Struktur Diagramm

Power Armored Kabel Spec. fir Ultraschall Ueleg Well

2. Type: YT-2*9.5/85


3. Kabel Design

1. Stroumkabel
1.1 Inner conductor: stranded by vanished wire, Nominal cross-sectional area 9.6mm2.
1.2 Isolatioun: speziellt héichtemperaturbeständegt Material, Wärmebeständnis ≥125, nominalen äusseren Duerchmiesser: 8.1mm.

2. Outer conductor: use copper wire braid structure, nominal outer diameter 9.2mm.

3. Sheath: special high temperature resistant material, heat resistance≥125℃, nominal outer diameter :12.2mm.

4. Reinforced layer: reinforce by steel wire stranding, nominal outer diameter : 16.6mm.

5. Outer sheath: rubber sheath, nominal outer diameter :19.5mm.

• Haaptapplikatiounen

Dëse Kabel gëtt fir Energieversuergung a Signaliwwerdroung vun Ënnerwaasserausrüstung am Ozean benotzt.

• Aarbechtszoustand

1. Schaffen Ëmgéigend Temperatur: -20 ℃ ~ + 70 ℃;
2. De Minimum zulässleche Biegsradius fir d'Installatioun ass 10 Mol vum Kabel baussenzegen Duerchmiesser;

• Technesch Leeschtung

Elektresch Leeschtung

schaffen Volt

AC3000V

Inner conductor DC resistance (Ω/km)(+20℃)

≤2.00

Outer conductor DC resistance (Ω/km)(+20℃)

≤2.15

Insulation resistance (MΩ·km)(DC500V)

≥500

Insulation electrical strength between inner and outer conductors (DC 10000V, 2min)

Insulation electrical strength between outer conductors and steel wires(DC 10000V, 2min)

Keng Ënnerdeelung

Mechanesch, kierperlech an Ëmweltvirstellung

1

Breaking force: ≥85 kN

2

Transverse water pressure (1MPa, 2h) (100m water depth) (sheath), no water leakage

Breaking Load Table

Power Armored Kabel Spec. fir Ultraschall Ueleg Well

Power Armored Kabel Spec. fir Ultraschall Ueleg Well

Kontaktéiert eis